Specially designed for use in environmental sampling applications
Altaflo® 2E0 Enviro Series FEP (fluorinated ethylene propylene) tubing is designed specifically for use in environmental sampling applications.
This cost effective tubing is the preferred product for applications requiring the purity of FEP without exposure to aggressive chemical or other harsh conditions.
Altaflo® 2E0 Series does not impart taste, odor or other contaminants which make it ideal for bailer tubes used in ground water applications.
For more critical application requirements, we suggest the use of Altaflo® 200 FEP or Altaflo® 400 PFA Tubing and Pipe.
FEP meets the requirements listed in ASTM D2116
-100° F to 400°
FEP is non-combustible and does not promote flame spread
| Part Number | ID | OD | OD Tol | Wall | Wall Tol |
|---|---|---|---|---|---|
| 2E0-0125-030-0C | .062 | .125 | .003 | 0.030 | .003 |
| 2E0-0250-030-XX | .190 | 1/4 | .004 | 0.030 | .003 |
| 2E0-0313-030-XX | 1/4 | 5/16 | .005 | 0.030 | .003 |
| 2E0-0375-030-XX | 5/16 | 3/8 | .005 | 0.030 | .003 |
| 2E0-0500-030-XX | 7/16 | 1/2 | .005 | 0.030 | .003 |
| 2E0-0250-040-XX | .170 | 1/4 | .005 | 0.040 | .003 |
| 2E0-0375-062-XX | 1/4 | 3/8 | .005 | 0.062 | .003 |
| 2E0-0500-062-XX | 3/8 | 1/2 | .005 | 0.062 | .003 |
Additional sizes up to 4” OD are available as custom extrusions — minimum order requirements may apply. Please contact Pexco’s office for details. This tubing is not recommended for aggressive chemical applications — please refer to Altaflo 200 or Altaflo 400.
| Part Number | OD | Wall | ID | Bend Radius | Working Pressure (PSI) |
|---|---|---|---|---|---|
| 2E0-0125-030-0C | 0.125 | 0.030 | .062 | 1/2″ | 360 |
| 2E0-0250-030-XX | 0.250 | 0.030 | .190 | 1″ | 195 |
| 2E0-0313-030-XX | 0.313 | 0.030 | .250 | 1-3/4″ | 156 |
| 2E0-0375-030-XX | 0.375 | 0.030 | .313 | 2-1/2″ | 130 |
| 2E0-0500-030-XX | 0.500 | 0.030 | .438 | 6″ | 97 |
| 2E0-0250-040-XX | 0.250 | 0.040 | .170 | 1″ | 260 |
| 2E0-0375-062-XX | 0.375 | 0.062 | .250 | 1″ | 269 |
| 2E0-0500-062-XX | 0.500 | 0.062 | .375 | 2″ | 200 |
The above information is based on tests performed at 73° F and can vary in individual applications based on parameters such as temperature, chemical concentration, pressure, etc. Please consult factory for details. For an estimate on burst pressure at ambient temperature we consider a 3:1 ratio when exposure temperature is 73° F. However Pexco does not recommend exceeding the suggested Working Pressure listed.
| Property | ASTM Test Method | Units | Value |
|---|---|---|---|
| Upper Service Temp. (Long Term) | — | °F | 400 |
| Specific Gravity | D 792 | — | 2.12–2.17 |
| Tensile Strength | D 1708 | PSI | 3,500 |
| Elongation | D 638 | % | 300–400 |
| Flex Modulus | D 790 | PSI | 90,000 |
| MIT Flex Life | D 2176 | cycles | 5,000 |
| Hardness | D 2240 | Shore D | 57–60 |